Program your water softener. Set the time of day, hardness and capacity if necessary. Here is where you will need to refer your owner's manual for your particular water softener settings and programming. Once your softener is programmed advance your controller to manual regeneration. The regeneration process can take a while. The two key features of the 760 Logix demand system are the microprocessor, and a water meter located on the valve outlet. The flow of soft water through the turbine meter generates electrical impulses that tell the computer the amount of water being used.
- Autotrol 255/760 Logix Water Softener Manual
- Logix 760 Water Softener Manual Troubleshooting
- Logix 760 Water Softener Manuals
The Logix 760 and 762 controllers are used primarily with the Autotrol 255 and 268 valves. There may come a time in the life of your water softener where you need to do a master reset of the Autotrol Logix controller. If your Autotrol control valve uses the Logix 760 or 762 controller then you can use these instructions to perform a master reset to get it back to the factory defaults. Warning - this reset procedure will erase all stored values including historical data. You'll know if you have a Logix 760 or 762 if yours looks like this:
Here's how to do the reset:
- Press and hold SET and DOWN simultaneously for 5 seconds.
- 'H0' and the system’s set resin volume (or 'F' mode) will be displayed.
- If a history value other than 'H0' is displayed, use the up arrow to scroll through the settings until 'H0' is displayed.
- To reset the control, press and hold SET for 5 seconds.
- The control will be reset to an un-programmed state.
Autotrol 255/760 Logix Water Softener Manual
The control valve is now reset to factory default values and you can proceed to the following resources for reprogramming instructions. Look for the section titled 'Initial Setup'
The most important step in the initial setup is to make sure that the media volume is set correctly. Here are the grain capacities for water softeners and corresponding resin volumes:
- 24,000 grain = 0.75 cubic feet
- 32,000 grain = 1.0 cubic feet
- 40,000 grain = 1.25 cubic feet
- 48,000 grain = 1.5 cubic feet
- 64,000 grain = 2.0 cubic feet
- 96,000 grain = 3.0 cubic feet
Logix 760 Water Softener Manual Troubleshooting
If you happened to find this page because you're looking for a new Autotrol softener, you're in luck - we sell them! And you can find them here.
Logix 760 Water Softener Manuals
Discussion in 'Water Softener Forum, Questions and Answers' started by Pitt742, Feb 8, 2012.
Forum | Title | Date |
---|---|---|
Water Softener Forum, Questions and Answers | Problem and Optimal Settings for Logix 762 with 268 Valve | Jul 28, 2015 |
Water Softener Forum, Questions and Answers | Logix 740 Timers, Blank Displays | Aug 18, 2016 |
Water Softener Forum, Questions and Answers | Logix 760 transformer | Feb 3, 2014 |
Water Softener Forum, Questions and Answers | Water Softener settings for Fleck 7000 | Dec 2, 2020 |
Water Softener Forum, Questions and Answers | Help with Softener Settings for 0.75 CUFT System | Nov 17, 2020 |